TESTINGUL 94 / ISO 3795 / BS 5852

Flammability & Fire Resistance Testing

Engineered Reaction to Fire Protection
ISO/IEC 17025 Accredited LaboratorySAC-SINGLASILAC-MRAUL 94 Standards AlignedTurnaround: 3 - 5 Working Days
Flammability & Fire Resistance Testing Laboratory Testing
Commercial Laboratory Testing & Inspection
Share This Post:

What is Flammability & Fire Resistance Testing testing?

Flammability testing measures how quickly materials catch fire, burn, drip molten flaming particles, and extinguish once the ignition source is removed.

Why Flammability & Fire Resistance Testing testing?

Fire safety codes across automotive, electronics, aerospace, and construction strictly prohibit rapid flame propagation materials. Compliance with UL 94 and ISO standards is mandatory for commercial sale.

How can GICG help?

Our laboratory features specialized vertical/horizontal flame cabinets, oxygen index analyzers, and glow-wire test rigs to provide accredited fire hazard classification.

Accredited Standards & Laboratory Protocols

Some of the flammability & fire resistance testing services provided by GICG include:

Polymer & Electronic Enclosure Flammability

UL 94 Classification
  • •Horizontal Burning Test (HB Rating: burn rate < 40 mm/min or < 75 mm/min)
  • •Vertical Burning Tests (V-0, V-1, V-2 Ratings: after-flame time < 10s / 30s)
  • •Flaming Dripping Evaluation onto surgical cotton indicator
  • •500 Watt (125 mm) Vertical Burn Test (5VA / 5VB Classifications)

Automotive Interior Flame Resistance

FMVSS 302 / ISO 3795
  • •Horizontal Burn Chamber Trial for fabrics, foams, and trims
  • •Flame Front Progression Measurement (Max burn rate: 102 mm/min)
  • •Self-Extinguishing (SE) and Burn-Rate (B) Classifications

Specialized Test Equipment & Instrumentation

Station 1

Digital UL 94 Vertical & Horizontal Flame Test Chamber with micro-burner & gas flow meters

Station 2

Glow-Wire Flammability Test Apparatus (ambient to 1000°C calibrated thermocouple)

Station 3

FMVSS 302 / ISO 3795 Automated Automotive Interior Burn Cabinet

Station 4

Limiting Oxygen Index (LOI) Chamber with Paramagnetic Oxygen Sensor

Critical Quality Checkpoints & Inspection Criteria

Total after-flame and after-glow duration after removal of methane ignition flame
Presence or absence of flaming droplets igniting bleached surgical cotton below the specimen
Linear burn rate in mm per minute along marked reference lines
Glow-wire ignition temperature (GWIT) and glow-wire flammability index (GWFI)

Official Laboratory Deliverables

ISO/IEC 17025 Accredited Flammability Assessment Report
UL 94 Flame Classification Certificate (V-0, V-1, V-2, HB)
High-resolution time-stamped video recording of burning and flame extinguishing

Frequently Asked Technical Questions

Q:What is the distinction between UL 94 V-0 and V-2 ratings?

Both V-0 and V-2 have short burning times, but V-0 specimens must not produce flaming drips that ignite cotton placed underneath, while V-2 allows flaming droplets provided the total burning duration remains within specification limits.

GICG Commercial Advantage

Let GICG help you to position your brand differently! Speak to us today!

Contact our accredited laboratory engineers for sample shipment guidance, test lead times, and tailored testing quotation packages for Flammability & Fire Resistance Testing.

Contact Testing Secretariat